Service manuals, schematics, eproms for electrical technicians

FLUKE 5440-SERIES 0-1100V,3-4PPM DC CALIBRATOR 1984 OP SM

METER - SERVICE MANUAL
Type: (PDF)
Size
3.7 MB
Page
94
Category
METER
SERVICE MANUAL
If you get stuck in repairing a defective appliance download this repair information for help. See below.
Good luck to the repair!

Please do not offer the downloaded file for sell only use it for personal usage!

Looking for similar fluke manual?
Advertisements
Document preview [1st page]
FLUKE 5440-SERIES 0-1100V,3-4PPM DC CALIBRATOR 1984 OP SM service manual (1st page)
Preview of FLUKE 5440-SERIES 0-1100V,3-4PPM DC CALIBRATOR 1984 OP SM [1st page]
Click on the link for free download!
Document preview [2nd page]
FLUKE 5440-SERIES 0-1100V,3-4PPM DC CALIBRATOR 1984 OP SM service manual (2nd page)
Preview of FLUKE 5440-SERIES 0-1100V,3-4PPM DC CALIBRATOR 1984 OP SM [2nd page]
Click on the link for free download!
Advertisements
Please tick the box below to get download link:
  • Also known:
    FLUKE DC CALIBRATOR 5440SERIES 01100V 34PPM 1984 OP 5440 SERIES 01100 34 PPM 1100V 4PPM 0-1100V 3-4PPM
  • If you have any question about repairing write your question to the Message board. For this no need registration.
  • If the site has helped you and you also want to help others, please Upload a manual, circuit diagram or eeprom that is not yet available on the site.
    Have a nice Day!
  • See related repair forum topics below. May be help you to repair.
Warning!
If you are not familiar with electronics, do not attempt to repair!
You could suffer a fatal electrical shock! Instead, contact your nearest service center!

Note! To open downloaded files you need acrobat reader or similar pdf reader program. In addition, some files are archived,
so you need WinZip or WinRar to open that files. Also some files are djvu so you need djvu viewer to open them.
These free programs can be found on this page: needed progs
If you use opera you have to disable opera turbo function to download file!
If you cannot download this file, try it with CHROME or FIREFOX browser.
Translate this page:
Relevant METER forum topics:
Fluke 8050A DMM Kijelző hiba
Üdv!   Átnézve a netet, nem igazán találtam egyszerű megoldást a javítására.  Kissé összefolyt a kijelzője, több ponton, óvatosan megnyomkodva most lehúzódott a folt az aljába egy sávba. Tulajdonképen most használható lett, ha középen megnyomom akkor a folt eltűnik és tökéletesnek tűnik, de vissza mászik egy sávba .  Van erre valami megoldás, vagy kuka ?
Fluke ScopeMeter 105B Series II Display frozen / no Display
In my case the display of the ScopeMeter was frozen and the keyboard did not respond any more exept the on/off key. This happened always after the ScopeMeter has been switched on for a while. To find the temperature effect, I heated up the different parts of the Digital A1 board with a hair dryer. At some point, the device display stopped working completely and only the backlight was working. This effect was steady and irreversible.
To repair the device, you need the "fluke_92b_96b_99b_105b_servicemanual" provided here in the service manual area.
On page 272 in Figure 9.2b (Digital A1 circuit diagram, part b) the display contrast circuit schematic shows the NPN Transistor V1432 of type BC848C (see also the attached picture). Measuring the Base/Emitter diode showed a low resistance of 100 Ohms in both directions. Replacing that transistor by a NPN transistor of type BC847C solved the problem and the device was working correctly again.
The reason for choosing the BC847C instead of the BC848C are the Vcbo and Vceo of only 30 V of the BC848x series. The BC847x series has a Vcbo of 50 V and a Vceo of 45 V respectively and offers therefore a greater margin. The V1432 is placed between TP431 (LCDPWR, +5 V) and the -30 V connection from Analog Board A2. These conditions are too close to the absolute maximum ratings of the BC848x and are especially for higher temperatures critical.
Philips-Fluke PM 6680 TIMER COUNTER alkatrész keresés átalakítás Megoldva
Tisztelt Urak!
Vásároltam a címben említett műszert, ami hibátlanul működik. 
A problémám a következő : A műszer az eredeti megrendelőnak anno a PM 9611/80 opcióval szállították, mert Rack-be építve használták.
Emiatt a 4 db lábat szakszerűen eltávolították, így  azt már nem kaptam meg a műszerhez.
Én viszont nem Rackben szeretném használni, ezért szeretnék az eredeti vagy ahhoz hasonló lábaket venni, vagy készíteni  (3 D nyomtatás megoldható)
Az is nagyon megfelelne ha valaki egy méretezett rajzot esetleg fotót tudna küldeni a lábakról. Tudom, hogy számtalan megoldással lehetne lábakat eszkábálni
a dobozra, de elegánsabb lenne az eredeti, vagy az eredeti alapján utángyártott  lábakat használni.
Az opció másik promlámája, ez már súlyosabb, Az A és B bemenetek  a hátlapra vannak kivezetve az előlapi csatlakozók- bár be vannak építve. értelemszerűen nem működnek. ( A user Manual-ban is le van írva) 
Az előlapi csatlakozásokkal kényelmesebben lenne használható a műszer.
A kérdésem illetve a segítség kérés arra vonatkozik, épített-e már valaki vissza előlapira csatlakozást, és mi módon lehet ezt kivitelezni?
Nem szívesen barmolnám szét a műszert bármilyen tanácsot szívesen fogadok. Szerszámokkal  és jártassággal rendelkezem  műszerek javításában, de azért óvatos vagyok.
Előre is köszönöm a segitséget
Üdv.:
Lajosf

Szétszedtem, és a gyári opció beszerelés  csak annyi ,hogy az előlapi BNC csatlakozók meleg pontjának fóliáját csk elvágták, és mögötte  kialakitott  PCB  furatba  egy SMA szerű aljzat van forrasztva amibe a hátlapra kivezetett  koaxok vannak bedugva.
A csatlakozókat széthúzva,  az elvágott fóliát összekötve  az előlapról is működik a műszer. 
 
fluke 123
sziasztok.van egy ilyen kis műszerem ,amiben ez az smd alkatrész szált el P43 ,vajon mi lehet ez?
Similar manuals:
If you want to join us and get repairing help please sign in or sign up by completing a simple electrical test
or write your question to the Message board without registration.
You can write in English language into the forum (not only in Hungarian)!

E-Waste Reduce