Dear,
A have a AWM4500 WHIRLPOOL.
The load of the water is correct and the program stops before the heating of the water.
The programmer is a SIEBE EC4477.03P13
I don't exactly know if the programmer wait for something after water load.
I have verified the following :
1) The switch of the door gives a contact : measured with a multimeter on connector A7 : got 230VAC.
2) The Pressostat switchs correctly and gives voltage on PIN B9 (to gives power to the heating element).
3) The program stops and no more happens. So, contact on B12 and B2 doesn't switch and heating element isn't powered.
4) If a connect 230 VAC on the little motor (TIM) it turns correctly.
Why the programmer stops and which information is missing?
What must I do to check the programmer or check the missing information?
Remark : the last cycle (water evacuation ) works correctly. Main Motors works correctly and the motor brushes are correct.
NTC resistor seems correct but give +/- 16K : in fact the temperature of the room is +/- 18 °C.
If I try a cold washing (to avoid heating issue), it is the same.
Best Regards
Hi!
Lenne ez a mikro.
Megy 1-2 sec-et és kimegy a hálózati bizti.
Néztem a ajtókapcsolókat a ventilátort a tányérforgató motort, jónak tűnnek.
Mi lehet?
A trafó??
kösz
Sziasztok . Bekapcsolás után program választás , start , szivattyú indul , megáll , vizet nem vesz , nem történik semmi , az időt vissza számlálja a végén újra szivattyúz és F1 . Ez már háromfázisú motorral , meg 10 év garanciás címkével 2019 -ben gyártott gép . Volt már valakinek szerencséje ilyen hibakódhoz ? Mi lehet a kínja ?
Kérdés a címben. Mit jelent a rácsszerű jel? Még nem láttam ilyet. Jó éjt.